SimNewB is designed to help improve neonatal resuscitation skills within the first 10 minutes of life.

This newborn, tetherless simulator has been designed to meet the specific learning objectives connected to neonatal resuscitation protocols.

Image could include transport and movement

Advanced training in neonatal resuscitation

SimNewB is a newborn tetherless simulator co-created with the American Academy of Pediatrics, designed to help improve neonatal resuscitation and to meet the specific learning objectives of neonatal resuscitation protocols.

Focusing on the first 10 minutes of life, SimNewB provides realistic training for critical interventions such as lung recruitment maneuvers and advanced airway management.

Learn to feel correct skills performance,

with an anatomically accurate airway

Learn to feel correct skills performance,

A closer look

A closer look

A closer look

PLACEHOLDER To be refined - image could be cross section of the SimNewB airway

The SimNewB airway has been designed with measurements and materials that will mean learners can feel the correct resistance and feel as they preform an airway management procedure.

The airway allows for training in all aspects of newborn airway management, including the use of Positive-Pressure Airway devices and the placement of ET tubes and LMAs.

Measure to improve resuscitation quality

For effective monitoring and review of CPR performance, QCPR Technology has been incorporated into SimNewB.

Key metrics measured include:

  • Correct compression depth
  • Approriate compression rate
  • Full release
  • Enough hands-on time
  • Adequate ventilation

Realistic anatomy ensures a learner performs correct head tilt, chin lift and experiences appropriate chest resistance and chest rise.

Partnering to improve neonatal outcomes

Developed in partnership with the American Academy of Pediatrics, SimNewB neonatal simulator will allow for new opportunities to integrate the latest technologies into neonatal training programs.

Pairing SimNewB and educational content developed and validated by organizations such as the American Academy of Pediatrics allows learners to master the skills needed to care for neonatal patients and ultimately improve patient outcomes.

Operation and Debriefing Options

Whether using SimPad PLUS or a LLEAP PC to run your simulation, the software is easy and efficient to use for scenario based training. The intuitive operating platforms provide flexible management of patient parameters, integrated data and video capture, as well as simulated patient monitoring capabilities. Choose the operating systems that works best for your training needs.

Integrated Debriefing

Capture, share and debrief training sessions using synchronised audio, video, and simulation information from one of Laerdal’s debriefing options:

SimView - an integrated debriefing solution giving you the ability to study simulation events more closely.
SimView Mobile - the perfect option for debriefing on-the-go- the system is portable, lightweight and easy to set up.
Session Viewer - enables audio and video capture from 1 HD USB web camera synchronized with the SimPad PLUS or LLEAP data log.

SimNewB has been designed by Laerdal with the American Academy of Pediatrics to meet the training requirements of neonatal emergency medicine and resuscitation courses. With realistic newborn traits and lifelike clinical feedback, SimNewB is ideal for training for the specific needs of neonates. 

Airway Features

  • Anatomically Accurate, Realistic Airway

  • ET Tube Insertion

  • LMA Insertion

  • Sellick Manoeuvre

  • Positive-Pressure Ventilation

  • Right Mainstem Intubation

  • Suctioning

  • Variable Lung Resistance

  • Gastric Tube Insertion

Breathing Features

  • Spontaneous breathing, with variable rate

  • Bilateral and unilateral chest rise and fall with mechanical ventilation

  • CO2 exhalation

  • Normal and abnormal breath sounds

  • Oxygen saturation

Breathing Complications

  • Pneumothorax

  • Unilateral chest movement with mechanical ventilation

  • Unilateral breath sounds

  • Unilateral needle thoracentesis, mid-axillary

Cardiac

  • Extensive ECG Library with rates from 10 - 300 bpm
  • ECG monitoring via 3-lead monitor

Vascular Access

  • Patent, cuttable umbilicus with venous and arterial access for bolus or infusion

  • Simulated blood flashback upon cannulation

Circulation

  • Heart Sounds

  • Umbilical and Brachial Pulse

  • Blood Pressure measured manually by auscultation of Korotkoff sounds

Sounds

  • Vocal: Grunt breathing, crying, hiccups and others

  • Lung: Normal, stridor, pneumonia and others

  • Heart: Normal, diastolic murmur, systolic murmur and others

Additional Features

  • Interchangeable pupils with normal, blown and constricted pupils

  • Movement in all four limbs: limp, tone, spontaneous motion and seizure

Session Viewer (PC operation)

  • Web-camera recording

  • Review event log together with synchronised recording of the patient monitor and in-room video

Educational Services

  • Introduction to SimNewB

  • Scenario Programming

  • Customised Educational Services

Technical Services

  • Professional Installation

  • Preventive Maintenance

  • Extended Warranty

Optional Accessories

220-03550

Congenital Anomalies Set

You must be logged in to submit the form.