Skip to content
Designed for Nursing Education

Nursing Anne Simulator

From basic assessment to advanced practice, Nursing Anne Simulator is designed based on input from leading nursing educators from around the world.

Raising the bar in simulation for nursing education

Nursing Anne Simulator can be used to train and verify skills for effective onboarding of new nurses as well as supporting annual competency training.

Learners can safely and realistically practice core nursing skills from basic assessments and critical thinking to advanced interventions.

Nursing Anne Simulator supports training in:

Fundamentals for nursing


Health Assessment


Mental Health

Nurse Orientation

Annual Competencies

Scenarios that bridge the gap from classroom to clinical practice

Enhanced clinical competence

Training scenarios have been built to help integrate simulation into existing educational curriculum.

Utilizing Nursing Anne Simulator with scenarios allow learners to practice a broad range of nursing competencies, and offer faculty the ability to provide realistic and challenging scenario-based simulations to help students build competence and confidence. 

Tailor scenarios for your training program

Laerdal also offers help to develop scenarios tailored to your specific needs. Together with your clinical subject matter experts, our educational experts can develop scenarios that support standardized delivery for improved learning outcomes and clinical impact. We will also support you in implementing these scenarios in your institution.

Operation and Debriefing Options


With its intuitive touchscreen interface, mobile design, easy-to-operate scenarios and integrated data log, SimPad PLUS will help you achieve learning objectives with greater ease.

LLEAP Instructor PC

LLEAP software unifies the control of all PC operated Laerdal simulators and helps you to conduct simulation training and develop new scenarios to meet your learning objectives with greater ease.

Integrated Debriefing

Capture, share and debrief training sessions using synchronised audio, video, and simulation information from one of Laerdal’s debriefing options.

Technical Services

Professionally trained Laerdal Service Engineers can provide product installation, preventive maintenance, and troubleshooting solutions to ensure your equipment works at its best, every time.

Educational Services

Laerdal Educational Services offer instructor-led on-site courses to help instructors implement best practices in simulation using hands-on interactive content.

Learn more


For the simulation novice to sophisticated developers, SimCenter has the tools and services to help every user realize their full potential.

Simulated Patient Monitor

Integrating a simulated patient monitor enhances clinical realism and will challenge critical thinking skills.

Enhanced Defibrillation

Pairing with ShockLink enables the use of a live defibrillator with training pads.

Already using a Nursing Anne?

Nursing Anne has been and will continue to be a reliable, trusted training tool for nursing education. 

Nursing Anne Simulator offers you a higher fidelity solution with additional training opportunities for nursing education. Our service team can help ensure minimal interruption should you wish to add Nursing Anne Simulator to your existing program.

Nursing Anne Simulator is available for pre-order and we expect the first shipment of ordered products to start March 2018.


Medication Administration

Administration of eardrops
Oral via NG tube
Bilateral pre-ported IV arms with capability for intravenous bolus or push through intravenous infusion when attached to a fluid bag
Optional female multi-venous IV training arm with capability of IV cannulation placement
Bilateral deltoid, ventral gluteal, dorsal gluteal and thigh injection sites
Palpable anatomy to aid in site selection includes anterior superior iliac crest, pubic symphysis and greater trochanter
Vaginal canal allows for insertion of vaginal suppositories or medications
Anal opening will accept real and simulated rectal suppositories


Wig for hair care procedures
Ear canal for practice of irrigation and cleaning
Oral care and hygiene
Removable upper denture for oral and denture care
Bed baths and skin care
Patient simulator shall allow manipulation into dorsal recumbent position for perineal care
Perineal care, including separation of the labia for cleansing

Skin Integrity and Wound Care

Patient positioning for prevention of pressure ulcers
Bandage and binder application
Nasal packing
Dressing and dressing changes
Toes spread for bandaging

Patient Handling

Full articulation for realistic patient handling procedures
Head can be flexed into chin to chest position and remain flexed until repositioned
Sits unassisted and bends at waist to tripod position
Protective positioning
Patient transfer techniques
Range of motion exercises


Accurate anatomical landmarks for insertion of NG Tube to correct measurement (nose to earlobe to xiphoid process)
Lavage and gavage
Invisible port in upper left abdomen for pre-placement of a PEG or J tube for feeding
Internal reservoir with 500mL fluid capacity, external quick fill port, and optional external bag for large volume feeding

Urinary Elimination

Female genitalia with realistic anatomy, includes labia majora, labia minora, urethral opening, clitoris, and vagina
Labia minora in naturally closed position, when opened exposes urethral opening
Manipulation into supine position with knees flexed is possible
Genitalia accepts straight or indwelling catheters
Genitalia attaches to an internal system including an internal urinary reservoir for urinary catheterization with ability to pressurize reservoir for proper fluid return
Intermittent closed catheter irrigation
Urinary reservoir has external quick access port for ease in filling

Bowel Elimination

Manipulation into Sims’ position for enema administration possible
Genitalia attaches to external reservoir bag for enema administration
Anal opening will accept real and simulated rectal suppositories
Ascending colostomy stoma with through hole connects to fluid reservoir for irrigation procedure
Three interchangeable stomas, include normal, dusky (non-perfusing), and infected
Changing and emptying ostomy appliance

Oxygenation & Perfusion

Realistic airway with uvula, epiglottis, vocal cords and esophagus
Various oxygen delivery methods with visible chest rise including nasal cannula, masks, trach collar/mask, CPAP device
Bag-mask ventilation
Suctioning (Oral & Nasopharyngeal)
Concealed port in neck for insertion of tracheostomy tube
Trach care tracheal suctioning with fluid
Ventilations with chest rise


CPR Capable
Oral/Nasal Intubation
Supraglottic Airway Insertion
BVM Ventilation
Head tilt/Chin lift
Jaw thrust w/articulated jaw
Sellick’s Manuver
Chest compressions with maximum compression depth of 70mm
ECG monitoring capabilities when used with SimPad PLUS, SimPad Classic or LLEAP, and ShockLink™
Defibrillation, cardioversion and pacing when used with ShockLink (training pads – apex and sternum)

Fluid, Electrolyte and Acid-Base Balance

Invisible port below the clavicle for pre-placement of central line catheter for site care, dressing change, flushing lines, and continuous or intermittent infusion
Internal central line reservoir with 500mL fluid capacity, with option to use an external reservoir bag for large volume infusions
Optional female multi-venous IV training arm with capability of IV cannulation placement, fluid administration and venipuncture

Scenarios and Debriefing

Operating system is capable of operating via Automatic Mode (pre-programmed scenarios) and Manual Mode (“on-the-fly” to modify the parameters of the scenario in real time)
Operating system can integrate with debriefing software, which combines synchronized student log, patient monitor display, live audio and video feed in a single debriefing file
System may be used with a web camera
Operating system can connect to an online store that sells pre-programmed scenarios and scenario aids that can be imported to the instructor remote or PC


Nursing Anne Simulator is compatible with the following systems/software:
LLEAP – Laerdal Learning Application, SimPad® PLUS System, SimPad® Classic System (backwards compatible), SimStore™, SimManager™, SimView™ / SimView™ Mobile, Session Viewer, ShockLink™

Optional Accessories

Zoll Defibrillator Connector (ShockLink), Physio Control® Quick Combo™ Connector (ShockLink)
Multi-Venous IV Training Arm


Pre-recorded single vocal sounds can be either played at a controllable volume, as a single occurrence or continuously repeated, including:
Cough, ­Moan, ­Vomit, ­SOB, Breathing (continuous sound), ­Scream, “Yes”, ­“No”
Optional wireless headset/ microphone allows user to talk through simulator


Blinking eyes with adjustable blink rate
Ability to open, close or partially close for consciousness cue
Interchangeable pupils (normal, dilated, constricted)


Spontaneous breathing synchronized with selected breath rate (0-60 bpm)
Bilateral or unilateral chest rise


Palpable pulse synchronized with ECG
Adjustable in strength (weak, normal and strong)
Bilateral carotid pulses (same pulse left and right)
Brachial and radial pulses in the right and left arm, with right and left independent control
Brachial pulse disabled and turned off if the pressure in the cuff is larger than 20 mmHg
Radial pulse turned off when the pressure in the BP cuff is larger or equal to the set systolic BP
Bilateral femoral pulses (same pulse left and right)
Bilateral pedal pulses with right and left independent control

Non-Invasive Blood Pressure

Bilateral measurement of non-invasive blood pressure (auscultated or palpated)
Korotkoff sounds synchronized with programmable ECG
Korotkoff volume control in 10 steps (0-9) available in both arms
Auscultatory gap on/ off feature
Pressure range of 0-300mmHg

Sounds Auscultation

Heart, lung and bowel sounds may be auscultated with real stethoscope when used with SimPad PLUS, SimPad Classic, or LLEAP

Lung Sounds

Anterior and posterior lung sounds synchronized with the set breathing rate (0-60 bpm) and chest rise on the manikin
­Normal, Coarse crackles, Fine crackles, Pleural rub, Pneumonia, Rhonchi, Stridor, Wheezes, No Sound
Lung sound and sound volume may be set individually for each lung – left and right, upper and lower
Anterior and posterior lung sound auscultation sites

Heart Sounds

Heart sounds synchronized with the ECG (QRS)
Normal, Aortic stenosis, Austin Flint Murmur, Friction Rub, Mitral Valve Prolapse, Systolic Murmur, Diastolic Murmur, OS@70ms / Open Snap MS
Non-perfusing rhythms will not generate heart sounds

Bowel Sounds

Four independently controlled auscultation areas for bowel sounds, centered around the umbilicus
Volume control in each quadrant
Bowel sounds are continuous repetitive sounds repeated infinitely
Normal, Hyperactive, Borborygmus, Hypoactive, No Sound
Auscultation of fetal heart tones, instead of bowel sounds, are available for auscultation from the abdomen
Fetal Normal 140bpm, Fetal Tachycardia 200bpm, Fetal Bradycardia 100bpm


Palpable anatomy for assessment and site location, including clavicle, sternum, spine, ribs (front and sides), xiphoid process, scapula, anterior superior iliac crest, pubic symphysis, and greater trochanter


Completely wireless and self-contained
Internal electrical and pneumatic power
Supplemental wired connectivity and power
Wirelessly integrates with existing computer networks
SimPad System (backwards compatible)
SimPad PLUS System
Laerdal Learning Application - LLEAP
Tablet PC Instructor – Patient Monitor, Rugged Table Instructor PC – Patient Monitor, Laptop LLEAP Instructor PC – Patient Monitor, All-in-One Panel PC Instructor-Patient Monitor
Wireless Headset
You must be logged in to submit the form.